Florida Pneumatic FP-1051A Use and Care Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
FP-1051A
7" STRAIGHT-HANDLE NEEDLE SCALER7" STRAIGHT-HANDLE NEEDLE SCALER
Ref. Description Part #
1 Anvil 109010
2 Barrel w/112020-1 425665
3 Piston 112020-1
4 Retaining pin 111230
7 Valve Block Assembly 425570-1
8 Valve block stop 121030
9 Lock nut 108160
10 Spring 118020
11 O-ring 115120
12 Trigger valve stem 120230
13 O-ring (2) 115160
14 Trigger valve body 120120
15 Retaining pin 111220
16 Safety lever 120330P
17 1/4” regulator 5711
18 Handle Assy 262371
19 Needle scaler housing 109060
20 Cap screw (2) 109070
21 Spring 109050
22 Needle holder 109030
23 Buffer 109040
24 Set of 19 needles 109020
Scaler attachment 109080
Complete
Specifications
Speed .......................................................................................................................... 3,700 BPM
Weight ........................................................................................................................... 4 5/8 lbs.
Overall length .................................................................................................................. 16-1/2
Average air consumption .................................................................................................4 CFM
Air inlet .......................................................................................................................... 1/4" NPT
Recommended hose size .............................................................................................. 3/8" I.D.
Maximum air pressure ....................................................................................................... 60 PSI
Tool Operation and Maintenance
'DLO\, before putting tool into operation,
disconnect air hose and pour 1/4 oz. of
air tool oil into the air inlet.
%ORw out air line to clear it of accumu-
lated dirt and moisture. Connect tool and
operate momentarily to allow oil to be
carried through tool.
+ose runs longer than 8 feet should be
connected to a 1/2” ID hose to provide
sufficient volume for proper performance.
We recommend oil made exclusively for
air tools or equivalents which include
moisture absorbants, rust inhibitors,
metal wetting agents and an EP (extreme
pressure) additive.
Florida Pneumatic’s Limited Warranty
Florida Pneumatic warrants their tools to be free from defects in material and work-
manship for tw o y
ears
from the date of purchase. This warranty does not apply to tools
which have been abused, misused, modified or repaired by someone other than
Florida Pneumatic or their authorized service centers. If a Florida Pneumatic tool
proves defective in material or workmanship within two
years
after purchase, return it to
any authorized service center or Florida Pneumatic freight prepaid. Please enclose
your name, address and adequate proof of purchase and a short description of the
defect. Florida Pneumatic will, at their option, repair or replace defective tools, free of
charge. Repairs or replacements are warranted as described above for the remainder
of the original warranty period. Florida Pneumatic sole liability and your exclusive
remedy under this warranty is limited to repair or replacement of the defective tool.
There are no other warranties expressed or implied and Florida Pneumatic shall not
be liable for incidental, consequential or special damages, or any other damages,
costs or expense of repair or replacement as described above.
7
4
Page view 1
1 2

Comments to this Manuals

No comments